LOW VOLUME AIR SAMPLER STAPLEX. Model : LV-2 and LV-4

Made in USA.

 

Accurate samples collected from immediate vicinity

Line and Battery powered models

Indoor, outdoor and underground use

Compact, lightweight, portable

Excellent for fast and nuisance dust and asbestos air sampling

 


Principle of Operation


Staplex Air Sampler draws low volumes of air through a filter by means of a rotary pump.

Various types and sizes of filter papers, glass fiber filter media, filter cassettes and activated carbon cartridges are suitable for collection of samples.

Flow rates are measured in liters per minute (LPM) .

Staplex Low Volume Air Samplers maximize flow rate and minimize sampling time for many air quality testing procedures, making them faster and more productive than personal samplers.

Sampling Range


LV-2 : 15-35 LPM

LV-4 : 3-25 LPM

BS, BSA : 5-17 LPM

Flow Control:


Fully adjustable flow control valve on direct-reading rotometer, settable over the full flow range.

Accurate to 5% full scale.

Inlet

Luer-lok fitting ( standard) or tapered fitting ( optional)

Analysis of Collect Samples

Gravimetric, taring, ashing, microscopic count, phase contrast or electron scanning microscopy, comparator, x-ray fluorescence, etc. depending on substance being sampled.

Description :


Portable, lightweight Low Volume Air Samplers highly effective for accurate samples from immediate vicinity of sampler for air pollutants; asbestos fibers; smoke and smog; radioactive particles; industrial, governmental, hospital, home and office health and safety tests; atmospheric conditions; mine air hazards; factory dusts; research and testing, etc. including chemical, radiological and toxicological analyses. Suitable for mobile or fixed position operation in normal non-explosive atmospheres.


 


Standard Models :


Line-powered Model :

LV-2 : 220-240 Volts AC, 50-60 Hz,

( 1 5-35 LPM)

Dimensions: 10.2 x 10.2 x 17.8 cm

LV-4 : 220-240 Volts AC, 50-60 Hz,

Dimensions : 11.4 x 14.6 x 23.5 cm .

Weight : 5 kg

(Specify 1-1/ 8” or 47-mm diameter filter holder when ordering)

 

Features:


LV-2 and LV-4 are capable of continuous use.

The sampling efficiency will cover up to 35 LPM of air with resistance pressure of 40 " WG (3 " Hg). Extremely compact and rugged.

 


Standard Components :


Motor, pump, built-in flowmeter (rotometer), 1-1/ 8 " diameter Filter Holder Assembly, convenient carrying handle.

Flow Control: Fully adjustable flow control valve on direct-reading rotometer, settable over the full flow range. Accurate to ± 5% full scale.

Self-charging, Battery-powered Models

Complete with Ni-Cad batteries and built-in re-charger

 


BSA : for 2 hour sampling time, recharge on 220-240 Volts AC, 50-60 Hz

Weight : 5.5 kg

Dimensions : 11.4 x 17.8 x 21.6 cm

Add " -T " for tapered inlet

Models with longer sampling time available by special order.

 BSA


Features :


Designed for use where electrical power is not available or practical, these Air Samplers are equipped with built-in self-charging Ni-Cad batteries and re-charger.


Standard Components: Motor, pump, flowmeter ( rotometer) , 1-1/ 8 " diameter filter holder assembly, NiCad batteries and self-charging circuit, all designed and built into a small compact unit with convenient carrying case.


Re-charging: To recharge batteries, plug cord set into proper voltage outlet: 220-240 volts AC for Overnight ( 14 hours) charge is sufficient to restore full charge. Ni-Cad battery cell life is unlimited and can be recharged as many times as required. Sampler should not be operated during recharge.


Accessories for Low Volume Air Samplers


Filter Holder Assemblies: Additional Filter Holder Assemblies save time and help avoid filter contamination when taking a series of samples.

Luer connection for quick changing.

SH18 Filter Holder Assembly, 1-1/ 8 " Diameter.

SH20 Filter Holder Assembly, 47 mm Diameter.

Filter Cassettes : Pre-loaded plastic styrene filter holders are very convenient and highly accurate.

 


PT. OCTA PRIMA LESTARI

Rukan Mitra Matraman Blok B-12  . Jl. Matraman Raya 148 - Jakarta 13150
Tlp : 85918154 -85918155 - 8512595 - 85902391 - 22856863                         

e-mail : meliati_layarda@octaprimalestari.com
Web : www.octaprimalestari.com

Tips Transaksi Aman

Indonetwork.co.id adalah direktori online yang mempertemukan pembeli dan penjual. Kami tidak menjamin transaksi yang terjadi diantara penjual dan pembeli, oleh karena itu kedua belah pihak diharap dapat berhati - hati dalam melakukan transaksi.

  • Telfon/email penjual sebelum transaksi.
  • Jangan terburu-buru transfer DP dengan janji harga murah,dsb.
  • Cek kesamaan semua dokumen KTP, invoice, nomor rekening, alamat usaha penjual, dsb.
  • Lakukan COD untuk pembelian pertama, jika lokasi memungkinkan.
Baca Selengkapnya >>>